Advance configuration
8
Zones types
CARDIO offers 16 programmable security inputs of 9 different types.
Delay: relevant to detectors associated with an entry delay (door, etc.)
Instant/delay (follower): relevant to detectors which can be triggered after a delay. For instance, the
front door has a contact and a motion detector has been installed in the lobby and set up with “instant
delay”. If someone enters through the door (which is the normal way to enter a house), both the
contact and the motion detector will wait until the delay has expired before sending out an emergency.
In the case someone enters the house through a window (which is not the normal way to enter a
house), the door contact will not be triggered but the motion detector will. In this case, there is no
delay attached to it and the system will send out an emergency call instantaneously.
Instant: there will be no time delay when a detector is triggered and an alarm will be sent out
immediately.
24hrs : (tamper) when a detector has to be armed continuously (24h/day) and cannot be armed or
disarmed from the screen or digital keys.
Interior: once again, we will use our previous example with a contact and a motion detector
associated with the “interior” status in this case. If someone inside the house turns the security ON,
the system will go through the exit delay before arming the security. If the person does not exit the
house before the end of the delay, the door contact will be armed but not the motion detector. This
means that this person will be able to stay in the house while protected from the outside (with the door
contact).
Inactive: when a zone is entered as inactive, it is inactive for security purposes only but can be used
for reaction (occupancy) purposes (see User’s Guide).
Fire: to declare a fire zone.
Medical: to declare a medical zone.
Panic: to declare a panic zone.
For each zone, choose from: EOL (end of line resistor), NO (normally open) and NC (normally close).
When there is no end-of-line resistor installed, it is mandatory to declare either NO or NC
.
For each zone, choose from 1 (Yes/No) can activate the siren or not 2 (Yes/No) can be bypassed or not.
Zones declared as panic, 24hrs, fire and medical cannot be bypassed, whatever data entered in the
bypass column (2).